user_mobilelogo

2 Gresham Street, London EC2

Date of independent inspection November 2008
Use of building Bank Offices
Date of construction 1996
Environment London centre - High traffic density
Evidence of regular cleaning or maintenance No
External parts of building which were anodised Window frames
Description of anodic colour and treatment Anolok™I Dark Bronze - 547
Type of anodising Batch
Anodiser United Anodisers: Heywood Metal Finishers, Huddersfield
Original anodic film layer on anodised parts (microns) Class 25 μm (AASC specifications)
Anodic film layer on date of independent inspection (microns) 29 μm
Visible signs of corrosion or surface degradation None
Conclusion No deterioration in anodic film protection after 12 years service life. No visible evidence of corrosion notwithstanding high density polluted urban environment. No discernable colour change.

Investec RBS Building

The World's leading Architectural Anodisers of Continuous Batch, Sheets, Plate, Profile and Specialist Products