2 Gresham Street, London EC2
Date of independent inspection | November 2008 |
Use of building | Bank Offices |
Date of construction | 1996 |
Environment | London centre - High traffic density |
Evidence of regular cleaning or maintenance | No |
External parts of building which were anodised | Window frames |
Description of anodic colour and treatment | Anolok™I Dark Bronze - 547 |
Type of anodising | Batch |
Anodiser | United Anodisers: Heywood Metal Finishers, Huddersfield |
Original anodic film layer on anodised parts (microns) | Class 25 μm (AASC specifications) |
Anodic film layer on date of independent inspection (microns) | 29 μm |
Visible signs of corrosion or surface degradation | None |
Conclusion | No deterioration in anodic film protection after 12 years service life. No visible evidence of corrosion notwithstanding high density polluted urban environment. No discernable colour change. |